What the calculator computes
Animated diagram of juice pasteurization on a plate heat exchanger: the product goes from the tank through the regenerator, the heating section, the holding tube and cooling to filling, and the particle colour shows the temperature at each point.
Set the product, flow, Brix, temperatures, holding time, heat recovery and steam pressure — you get the steam flow, heating power, savings from heat recovery, cooling water, section areas and plate count, holding tube length, holding equivalent at 93 °C and PU, a temperature chart along the path and warnings. You can build a juice line right away. The model is indicative.