Calculation example
- Mode
- Holding time for the required PU
- Temperature (stage 1)
- 65 °C
- Required PU
- 15 PU
- Required holding time
- 2,9 min
- PU per minute at the stage 1 temperature
- 5,245 PU/min
Enter the holding temperature and the number of PU your process requires — you get the time. At 65 °C each minute gives about 5.2 PU.
Approximate calculation using a simplified model: for designing equipment and process modes, consult a technologist.
How does temperature affect the holding time?
A rise of 10 °C shortens the required time roughly 26-fold.
The calculations are approximate: they help to assess the process and compare options, but do not replace a process design and trials on a specific raw material. This section is for reference only and contains no commercial offers.